CAM – Centro de Arte Moderna Gulbenkian

Country

Portugal

Architecture

Kengo Kuma & Associates

Photography

FG + SG - Fotografia de Arquitectura

About the project

The Centro de Arte Moderna (CAM), nestled within the lush grounds of the Calouste Gulbenkian Foundation, showcases an innovative architectural approach that harmonizes art and nature, as conceptualized by Kengo Kuma. In collaboration with OODA and VDLA, the project features a striking ceramic tile canopy that enhances its visual appeal and functionality, reflecting a human-centered design philosophy.

A key highlight of this redesign is the integration of indoor and outdoor spaces, inspired by the Japanese concept of Engawa, which fosters a seamless connection between the interior and the surrounding landscape. Custom pivot and sliding glass systems developed by OTIIMA play a crucial role in this transformation, offering unobstructed views of the gardens and promoting an interactive experience between art and nature.

Compare products

Compare products easily by analyzing features and specifications side by side to find the best option for your needs.

thermal-transmittance

Thermal Transmittance

watertightness

Watertightness

air-permeability

Air permeability

wind-resistance

Wind resistance

resistance

Impact resistance

insulation

Sound insulation

security

Security

thermal-transmittance

Thermal Transmittance

Uw Ug = 1,0 (38mm)
Uw Ug = 0.5 (54mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

E1200 (54mm)

(4 classes above 9A) 1

air-permeability

Air permeability

ISO EN 12207 + ISO EN 1026

Class 4

(600 Pa or 119 Km/h) 1 2

wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class C5

(in 6 possible classes) 2

resistance

Impact resistance

ISO EN 12600 + ISO EN 1630

Class 5

(2000 Pa or 200 Km/h)

insulation

Sound insulation

ISO EN 10140 + ISO EN 717

Rw: 42 db (up to)
security

Security

ISO EN 1628 + ISO EN 1629 + ISO EN 1630

RC2: (WK2)

3

thermal-transmittance

Thermal Transmittance

Uw Ug = 1,0 (38mm)
Uw Ug = 0.5 (54mm)
Uw Ug = 0.47 (62mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

E1200

(7 classes above 9A) 1

air-permeability

Air permeability

ISO EN 12207 + ISO en 1026

Class 4

(600 Pa or 110 Km/h) 1

wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class B5

(2000 Pa or 200 Km/h) 1

resistance

Impact resistance

ISO EN 12600 + ISO EN 1630

Class 5 (38mm / 54mm)

1C1 | 2B2 | 1B1 2 (62mm)

insulation

Sound insulation

ISO EN 10140 + ISO EN 717

Rw: 42 db (up to) (38mm / 54mm)

Rw: 44 db (up to) (62mm)

security

Security

ISO EN 1628 + ISO EN 1629 + ISO EN 1630

RC2: (WK2)

3

thermal-transmittance

Thermal Transmittance

Uw Ug = 1.0 (38mm)
Uw Ug = 0.5 (54mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

E1650

(7 Clases superior a 9A) 1

air-permeability

Air permeability

ISO EN 12207 + ISO EN 1026

Class 4

(600 Pa or 110 Km/h) 1

wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class C5

(2000 Pa or 200 Km/h) 1

resistance

Impact resistance

ISO EN 12600 + ISO EN 1630

Class 5
insulation

Sound insulation

ISO EN 10140 + ISO EN 717

Rw: 42 db (up to)
security

Security

ISO EN 1628 + ISO EN 1629 + ISO EN 1630

RC2: (WK2)

2

thermal-transmittance

Thermal Transmittance

Uw Ug = 0.7 (38mm)
Uw Ug = 0.7 (54mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

Class 8A

(450 Pa or 95 km/h)

air-permeability

Air permeability

ISO EN 12207 + ISO en 1026

Class 3

(600 Pa or 110 Km/h)

wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class C5

(2000 Pa or 200 Km/h)

resistance

Impact resistance

ISO EN 12600 + ISO EN 1630

Class 5

(in 6 possible classes)

insulation

Sound insulation

ISO EN 10140 + ISO EN 717

Rw: 38 db (up to)
security

Security

RC2: (WK2) 2

RC2: (WK2)

Newsletter

OTIIMA - Much more than a window

Subscribe