The Future of Minimalist Design: Vision System by OTIIMA

When it comes to architectural glazing, the principle of “less is often more” guides OTIIMA’s Vision system, a revolutionary window solution that redefines minimalism, engineering, and elegance. Designed for an ideal balance of transparency, precision, and performance, the Vision system transforms the way windows look, feel, and function. 

Minimal Aluminum, Maximum Light

At the core of the Vision system is a radical design philosophy: reducing the visible aluminum to enhance natural light. By concealing the top and bottom rails within recessed outer frames, Vision creates a flush, seamless opening that provides uninterrupted views and continuous daylight.  

Whether opting for a standard horizontal sliding panel, a corner opening, or a hidden pocket system, you can expect pure transparency combined with architectural integrity. 

Engineered for Performance

The Vision system is not just beautiful; it’s also engineered for exceptional performance. Its three series-38, 54, and the advanced 62-offer superior thermal insulation, with U-values as low as Uw 0.5 W/m²K, making them perfect for energy-efficient buildings. Additionally, with Rw ratings of up to 42 dB, the acoustic insulation is impressive, ensuring peaceful and private interiors even in noisy environments. 

Smart Features, Invisible Design

OTIIMA believes that the best technology is the kind you don’t notice. That’s why the Vision system integrates features such as: 

  • Exclusive invisible locks 
  • Full-frame flyscreens 
  • Curved glass options 
  • Custom rail configurations (mono, bi, and tri-rail) 
  • Hidden bearings and motorized automation 
  • Anti-freeze locking systems for extreme climates 

 

Every detail is carefully designed to improve the user experience while remaining unobtrusive. 

Vision is much more than a Window

The Vision system speaks to architects who prioritize light and high performance without compromise. It embodies a dedication to modern architecture, advanced engineering, and sustainable comfort. Whether designing a luxury residence or a high-performance facade, OTIIMA’s Vision is more than just a window system; it’s a foundation for the future. 

Compare products

Compare products easily by analyzing features and specifications side by side to find the best option for your needs.

thermal-transmittance

Thermal Transmittance

watertightness

Watertightness

air-permeability

Air permeability

wind-resistance

Wind resistance

resistance

Impact resistance

insulation

Sound insulation

security

Security

thermal-transmittance

Thermal Transmittance

Uw Ug = 1,0 (38mm)
Uw Ug = 0.5 (54mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

E1200 (54mm)

(4 classes above 9A) 1

air-permeability

Air permeability

ISO EN 12207 + ISO EN 1026

Class 4

(600 Pa or 119 Km/h) 1 2

wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class C5

(in 6 possible classes) 2

resistance

Impact resistance

ISO EN 12600 + ISO EN 1630

Class 5

(2000 Pa or 200 Km/h)

insulation

Sound insulation

ISO EN 10140 + ISO EN 717

Rw: 42 db (up to)
security

Security

ISO EN 1628 + ISO EN 1629 + ISO EN 1630

RC2: (WK2)

3

thermal-transmittance

Thermal Transmittance

Uw Ug = 1,0 (38mm)
Uw Ug = 0.5 (54mm)
Uw Ug = 0.47 (62mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

E1200

(7 classes above 9A) 1

air-permeability

Air permeability

ISO EN 12207 + ISO en 1026

Class 4

(600 Pa or 110 Km/h) 1

wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class B5

(2000 Pa or 200 Km/h) 1

resistance

Impact resistance

ISO EN 12600 + ISO EN 1630

Class 5 (38mm / 54mm)

1C1 | 2B2 | 1B1 2 (62mm)

insulation

Sound insulation

ISO EN 10140 + ISO EN 717

Rw: 42 db (up to) (38mm / 54mm)

Rw: 44 db (up to) (62mm)

security

Security

ISO EN 1628 + ISO EN 1629 + ISO EN 1630

RC2: (WK2)

3

thermal-transmittance

Thermal Transmittance

Uw Ug = 1.0 (38mm)
Uw Ug = 0.5 (54mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

E1650

(7 Clases superior a 9A) 1

air-permeability

Air permeability

ISO EN 12207 + ISO EN 1026

Class 4

(600 Pa or 110 Km/h) 1

wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class C5

(2000 Pa or 200 Km/h) 1

resistance

Impact resistance

ISO EN 12600 + ISO EN 1630

Class 5
insulation

Sound insulation

ISO EN 10140 + ISO EN 717

Rw: 42 db (up to)
security

Security

ISO EN 1628 + ISO EN 1629 + ISO EN 1630

RC2: (WK2)

2

thermal-transmittance

Thermal Transmittance

Uw Ug = 0.7 (38mm)
Uw Ug = 0.7 (54mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

Class 8A

(450 Pa or 95 km/h)

air-permeability

Air permeability

ISO EN 12207 + ISO en 1026

Class 3

(600 Pa or 110 Km/h)

wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class C5

(2000 Pa or 200 Km/h)

resistance

Impact resistance

ISO EN 12600 + ISO EN 1630

Class 5

(in 6 possible classes)

insulation

Sound insulation

ISO EN 10140 + ISO EN 717

Rw: 38 db (up to)
security

Security

RC2: (WK2) 2

RC2: (WK2)