Pavilion Sestig

Country

Belgium

Architecture

Glenn Sestig Architects

Photography

Jean-Pierre Gabriel

About the project

In the idyllic village of Deurle, Belgium, situated along the serene river Lys, stands a villa that masterfully bridges past and future. Initially conceived by Ivan Van Mossevelde for an art collector, this building has been skillfully transformed into the headquarters of Glenn Sestig Architects. This renovation honors the villa’s history and introduces contemporary sensibility.

The restoration emphasizes a fluid dialogue between the interior and exterior spaces. OTIIMA’s elegant window frames, featuring self-supporting clear glass and slender aluminum profiles, facilitate this connection, enabling an uninterrupted flow of natural light throughout the residence. The villa’s symmetrical layout, central patio, and selected materials—including natural stone flooring and indirect lighting—forge a dramatic and tranquil atmosphere. Highlighted in ARK JOURNAL, the Matthys-Colle House is an architectural icon and a celebration of 50 years of design evolution, preserving its original essence while boldly embracing a new future.

Compare products

Compare products easily by analyzing features and specifications side by side to find the best option for your needs.

thermal-transmittance

Thermal Transmittance

watertightness

Watertightness

air-permeability

Air permeability

wind-resistance

Wind resistance

resistance

Impact resistance

insulation

Sound insulation

security

Security

thermal-transmittance

Thermal Transmittance

Uw Ug = 1,0 (38mm)
Uw Ug = 0.5 (54mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

E1200 (54mm)

(4 classes above 9A) 1

air-permeability

Air permeability

ISO EN 12207 + ISO EN 1026

Class 4

(600 Pa or 119 Km/h) 1 2

wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class C5

(in 6 possible classes) 2

resistance

Impact resistance

ISO EN 12600 + ISO EN 1630

Class 5

(2000 Pa or 200 Km/h)

insulation

Sound insulation

ISO EN 10140 + ISO EN 717

Rw: 42 db (up to)
security

Security

ISO EN 1628 + ISO EN 1629 + ISO EN 1630

RC2: (WK2)

3

thermal-transmittance

Thermal Transmittance

Uw Ug = 1,0 (38mm)
Uw Ug = 0.5 (54mm)
Uw Ug = 0.47 (62mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

E1200

(7 classes above 9A) 1

air-permeability

Air permeability

ISO EN 12207 + ISO en 1026

Class 4

(600 Pa or 110 Km/h) 1

wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class B5

(2000 Pa or 200 Km/h) 1

resistance

Impact resistance

ISO EN 12600 + ISO EN 1630

Class 5 (38mm / 54mm)

1C1 | 2B2 | 1B1 2 (62mm)

insulation

Sound insulation

ISO EN 10140 + ISO EN 717

Rw: 42 db (up to) (38mm / 54mm)

Rw: 44 db (up to) (62mm)

security

Security

ISO EN 1628 + ISO EN 1629 + ISO EN 1630

RC2: (WK2)

3

thermal-transmittance

Thermal Transmittance

Uw Ug = 1.0 (38mm)
Uw Ug = 0.5 (54mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

E1650

(7 Clases superior a 9A) 1

air-permeability

Air permeability

ISO EN 12207 + ISO EN 1026

Class 4

(600 Pa or 110 Km/h) 1

wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class C5

(2000 Pa or 200 Km/h) 1

resistance

Impact resistance

ISO EN 12600 + ISO EN 1630

Class 5
insulation

Sound insulation

ISO EN 10140 + ISO EN 717

Rw: 42 db (up to)
security

Security

ISO EN 1628 + ISO EN 1629 + ISO EN 1630

RC2: (WK2)

2

thermal-transmittance

Thermal Transmittance

Uw Ug = 0.7 (38mm)
Uw Ug = 0.7 (54mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

Class 8A

(450 Pa or 95 km/h)

air-permeability

Air permeability

ISO EN 12207 + ISO en 1026

Class 3

(600 Pa or 110 Km/h)

wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class C5

(2000 Pa or 200 Km/h)

resistance

Impact resistance

ISO EN 12600 + ISO EN 1630

Class 5

(in 6 possible classes)

insulation

Sound insulation

ISO EN 10140 + ISO EN 717

Rw: 38 db (up to)
security

Security

RC2: (WK2) 2

RC2: (WK2)

Newsletter

OTIIMA - Much more than a window

Subscribe