House in Vila Real

Country

Portugal

Architecture

Sebastião Moreira

Photography

João Ferrand

About the project

The House in Vila Real, designed by Sebastião Moreira, exemplifies architectural restraint, prioritizing clarity in form and materiality to create a pure, timeless aesthetic. The single-story structure extends laterally within a tranquil landscape, fostering a subtle interaction with its natural environment. This composition utilizes a minimalist vernacular with clean geometric lines and a warm-toned façade. The design features a deliberate interplay between solid and void, enhancing the integration of built space with the surrounding nature.

A significant aspect of this project is the expansive roof projection, which reinforces the design’s horizontal orientation while providing shelter and underscoring the structure’s lightness. A key component of this spatial continuity is OTIIMA Plus windows, designed to eliminate the barrier between interior and exterior spaces. The floor-to-ceiling glass panels optimize the ingress of natural light, shaping the interior environments and creating a fluid transition to the outdoor areas. This approach distills architecture to its fundamental aspects—light, space, and materiality—culminating in an elegant and understated residential experience.

Compare products

Compare products easily by analyzing features and specifications side by side to find the best option for your needs.

thermal-transmittance

Thermal Transmittance

watertightness

Watertightness

air-permeability

Air permeability

wind-resistance

Wind resistance

resistance

Impact resistance

insulation

Sound insulation

security

Security

thermal-transmittance

Thermal Transmittance

Uw Ug = 1,0 (38mm)
Uw Ug = 0.5 (54mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

E1200 (54mm)

(4 classes above 9A) 1

air-permeability

Air permeability

ISO EN 12207 + ISO EN 1026

Class 4

(600 Pa or 119 Km/h) 1 2

wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class C5

(in 6 possible classes) 2

resistance

Impact resistance

ISO EN 12600 + ISO EN 1630

Class 5

(2000 Pa or 200 Km/h)

insulation

Sound insulation

ISO EN 10140 + ISO EN 717

Rw: 42 db (up to)
security

Security

ISO EN 1628 + ISO EN 1629 + ISO EN 1630

RC2: (WK2)

3

thermal-transmittance

Thermal Transmittance

Uw Ug = 1,0 (38mm)
Uw Ug = 0.5 (54mm)
Uw Ug = 0.47 (62mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

E1200

(7 classes above 9A) 1

air-permeability

Air permeability

ISO EN 12207 + ISO en 1026

Class 4

(600 Pa or 110 Km/h) 1

wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class B5

(2000 Pa or 200 Km/h) 1

resistance

Impact resistance

ISO EN 12600 + ISO EN 1630

Class 5 (38mm / 54mm)

1C1 | 2B2 | 1B1 2 (62mm)

insulation

Sound insulation

ISO EN 10140 + ISO EN 717

Rw: 42 db (up to) (38mm / 54mm)

Rw: 44 db (up to) (62mm)

security

Security

ISO EN 1628 + ISO EN 1629 + ISO EN 1630

RC2: (WK2)

3

thermal-transmittance

Thermal Transmittance

Uw Ug = 1.0 (38mm)
Uw Ug = 0.5 (54mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

E1650

(7 Clases superior a 9A) 1

air-permeability

Air permeability

ISO EN 12207 + ISO EN 1026

Class 4

(600 Pa or 110 Km/h) 1

wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class C5

(2000 Pa or 200 Km/h) 1

resistance

Impact resistance

ISO EN 12600 + ISO EN 1630

Class 5
insulation

Sound insulation

ISO EN 10140 + ISO EN 717

Rw: 42 db (up to)
security

Security

ISO EN 1628 + ISO EN 1629 + ISO EN 1630

RC2: (WK2)

2

thermal-transmittance

Thermal Transmittance

Uw Ug = 0.7 (38mm)
Uw Ug = 0.7 (54mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

Class 8A

(450 Pa or 95 km/h)

air-permeability

Air permeability

ISO EN 12207 + ISO en 1026

Class 3

(600 Pa or 110 Km/h)

wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class C5

(2000 Pa or 200 Km/h)

resistance

Impact resistance

ISO EN 12600 + ISO EN 1630

Class 5

(in 6 possible classes)

insulation

Sound insulation

ISO EN 10140 + ISO EN 717

Rw: 38 db (up to)
security

Security

RC2: (WK2) 2

RC2: (WK2)