Canada
Openspace Architecture
Ema Peter Photography
Bowing Cedar, designed by Openspace Architecture, sits on a forested waterfront property overlooking the Saanich Inlet in British Columbia, Canada. Guided by proportion and simplicity, and influenced by Japanese architecture, the single-level residence follows the land’s natural contours. Its gently curved form adapts to the topography, preserves mature trees, and frames views of the forest and water. Western red cedar, sandstone, and limestone, chosen for their durability, texture, and natural weathering, tie the house to its surroundings, while deep roof overhangs and covered terraces extend the living areas outdoors and soften the boundary between inside and out. Extensive glazing brings natural light deep into the interior and frames changing views of the forest and coastline.
That level of transparency came with a technical challenge. Located in British Columbia, the residence was designed to meet Passive House criteria, which placed significant demands on the thermal performance of the window system and made early coordination among architecture, engineering, and manufacturing essential. OTIIMA worked with the architectural and engineering teams to develop solutions for the openings throughout the house, combining 38 Open, 38 Classic, 54 Open, and 54 Classic. Together, these systems address diverse structural configurations and strict thermal targets while keeping a consistent visual language across the building. Bowing Cedar shows that transparency and energy efficiency can coexist: a house open to its surroundings and responsive to its site conditions.
Compare products easily by analyzing features and specifications side by side to find the best option for your needs.
Uw 1.87 W / m2 K (26mm)
Uw 1.58 W / m2 K (38mm)
Uw 1.07 W / m2 K (54mm)
ISO EN 12208 + ISO EN 1027
ISO EN 12207 + ISO EN 1026
ISO EN 12210 + ISO EN 12211
ISO EN 10140 + ISO EN 717
ISO EN 1628 + ISO EN 1629 + ISO EN 1630
Uw 1.56 W / m2 K (38mm)
Uw 1.06 W / m2 K (54mm)
Uw 0.89 W / m2 K (62mm)
ISO EN 12208 + ISO EN 1027
ISO EN 12207 + ISO en 1026
ISO EN 12210 + ISO EN 12211
ISO EN 10140 + ISO EN 717
ISO EN 1628 + ISO EN 1629 + ISO EN 1630
Uw 1.61 W / m2 K (38mm)
Uw 1.08 W / m2 K (54mm)
ISO EN 12208 + ISO EN 1027
ISO EN 12207 + ISO EN 1026
ISO EN 12210 + ISO EN 12211
ISO EN 10140 + ISO EN 717
ISO EN 1628 + ISO EN 1629 + ISO EN 1630
Uw 1.55 W / m2 K (38mm)
Uw 1.07 W / m2 K (54mm)
ISO EN 12208 + ISO EN 1027
ISO EN 12207 + ISO en 1026
ISO EN 12210 + ISO EN 12211
ISO EN 10140 + ISO EN 717
RC2: (WK2) 2