OTIIMA expands its international partner network

Architecture happens through collaboration among engineers, architects, installers, and specialists who work with discipline.

We believe excellence is not scalable without rigor. For that reason, our international growth has never been based on volume. It has been based on alignment.

Today, we are opening applications to expand our global partner network.

A network built on high standards

OTIIMA systems are designed to disappear visually while performing at the highest technical level. Ultra-minimal sightlines, large spans, demanding climates, and complex customizations are the standard.

Delivering this level consistently across different markets requires shared vision and values.

Our partners are companies capable of representing OTIIMA’s philosophy locally, technically, commercially, and culturally.

This is a curated network.

Gulbenkian Modern Art Center | Kengo Kuma & Associates + OODA + VLDA | © Fernando Guerra

Across climates and cultures

Architecture is influenced by its context, including factors such as climate, regulations, construction culture, and aesthetic preferences, which differ from country to country. However, the performance of a building should remain consistent.

Our partner network spans multiple regions, all committed to delivering minimal architecture with precision and reliability, regardless of location. This consistency protects both the project and the brand.

A selective expansion

We are currently evaluating new markets and strengthening our presence in strategic regions worldwide.

Companies that believe their expertise, positioning, and operational standards align with OTIIMA are invited to submit a partnership application for review.

Every application is assessed individually, and selection is based on technical capability, strategic fit, and long-term vision.

Banánka House | Pauliny Hovorka Architekti | © Matej Hakár

Apply for a partnership

If your company is prepared to represent a global minimum standard of responsibility, we invite you to apply.

Explore the partnership criteria and submit your application here.

Compare products

Compare products easily by analyzing features and specifications side by side to find the best option for your needs.

thermal-transmittance

Thermal transmittance

watertightness

Watertightness

air-permeability

Air permeability

wind-resistance

Wind resistance

insulation

Acoustic insulation

security

Resistance class

thermal-transmittance

Thermal Transmittance

Uw 1.87 W / m2 K (26mm)
Uw 1.58 W / m2 K (38mm)
Uw 1.07 W / m2 K (54mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

up to E900 (26mm)
up to E1050 (38mm)
up to E1200 (54mm)
air-permeability

Air permeability

ISO EN 12207 + ISO EN 1026

up to Class 3 (26mm)
up to Class 4 (38mm)
up to Class 4 (54mm)
wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class B3 (26mm)
Class C5 (38mm)
Class B4 (54mm)
insulation

Sound insulation

ISO EN 10140 + ISO EN 717

up to 42 db
security

Security

ISO EN 1628 + ISO EN 1629 + ISO EN 1630

RC2: (WK2) *1
thermal-transmittance

Thermal Transmittance

Uw 1.56 W / m2 K (38mm)
Uw 1.06 W / m2 K (54mm)
Uw 0.89 W / m2 K (62mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

up to E1200 (38 mm)
air-permeability

Air permeability

ISO EN 12207 + ISO en 1026

up to Class 4 (38 mm)
wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class B5 (38 mm)
insulation

Sound insulation

ISO EN 10140 + ISO EN 717

up to 38 db
security

Security

ISO EN 1628 + ISO EN 1629 + ISO EN 1630

RC2: (WK2) *1
thermal-transmittance

Thermal Transmittance

Uw 1.61 W / m2 K (38mm)
Uw 1.08 W / m2 K (54mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

up to E1650 (38 mm)
air-permeability

Air permeability

ISO EN 12207 + ISO EN 1026

up to Class 4 (38 mm)
wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class C5 (38 mm)
insulation

Sound insulation

ISO EN 10140 + ISO EN 717

up to 40 db
security

Security

ISO EN 1628 + ISO EN 1629 + ISO EN 1630

RC2: (WK2) *1
thermal-transmittance

Thermal Transmittance

Uw 1.55 W / m2 K (38mm)
Uw 1.07 W / m2 K (54mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

up to Class 8A (38 mm)
up to Class 8A (54mm)
air-permeability

Air permeability

ISO EN 12207 + ISO en 1026

up to Class 3 (38 mm)
up to Class 4 (54mm)
wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class B3 (38 mm)
Class C4 (54mm)
insulation

Sound insulation

ISO EN 10140 + ISO EN 717

up to 38 db
security

Security

RC2: (WK2) 2

RC2: (WK2) *1

Newsletter

OTIIMA - Much more than a window

Subscribe