Elemental’s EDP Headquarters: Pioneering Sustainable Architecture

At the intersection of form and function lies a monument to contemporary architecture, where every angle and every curve tells a story of purposeful design and ecological awareness. Conceived by the visionary mind of Alejandro Aravena and his team, Elemental, the EDP headquarters transcends conventional paradigms to redefine what it means to build sustainably in the 21st century. 

Sustainable Design

Aravena’s social and environmental responsibility ethos permeates every aspect of the EDP headquarters. From the outset, the project was conceived as more than a corporate building; it is a living, breathing testament to the harmonious coexistence of nature and modernity. The building’s design seamlessly integrates passive strategies for energy efficiency, utilizing natural light and ventilation to minimize reliance on artificial systems. Its façade, adorned with OTIIMA windows,enhances aesthetic appeal and maximizes thermal performance, ensuring optimal occupant comfort while reducing energy consumption. 

 

Read Also- Enhancing Architectural Spaces: Maximizing Natural Light with OTIIMA windows 

© Iwan Baan

Innovative Spaces

In addition to its sustainable features, the EDP headquarters fosters a culture of collaboration and creativity through its innovative spatial configuration. Aravena’s signature “social architecture” approach is evident in the building’s layout, which prioritizes communal areas and flexible workspaces over traditional hierarchical structures. This deliberate emphasis on connectivity and interaction reflects a broader commitment to employee well-being and organizational agility. 

© francisco nogueira

Community Impact

The EDP headquarters transcends its role as a corporate entity to catalyze positive change in the surrounding community. Its public spaces, including a landscaped plaza and cultural center, invite engagement and dialogue, bridging the gap between the built environment and the people it serves. By applying principles of inclusivity and accessibility, Aravena has transformed the EDP headquarters into a symbol of hope and inspiration for Lisbon and beyond. 

© Yoshihiro Koitani

© francisco nogueira

In an era defined by the urgent imperative of sustainability, ELEMENTAL’s EDP headquarters stands as a testament to the transformative power of architecture. More than just a building, it represents a paradigm shift in our design approach, prioritizing environmental stewardship, social responsibility, and human-centered innovation. 

Compare products

Compare products easily by analyzing features and specifications side by side to find the best option for your needs.

thermal-transmittance

Thermal transmittance

watertightness

Watertightness

air-permeability

Air permeability

wind-resistance

Wind resistance

insulation

Acoustic insulation

security

Resistance class

thermal-transmittance

Thermal Transmittance

Uw 1.87 W / m2 K (26mm)
Uw 1.58 W / m2 K (38mm)
Uw 1.07 W / m2 K (54mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

up to E900 (26mm)
up to E1050 (38mm)
up to E1200 (54mm)
air-permeability

Air permeability

ISO EN 12207 + ISO EN 1026

up to Class 3 (26mm)
up to Class 4 (38mm)
up to Class 4 (54mm)
wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class B3 (26mm)
Class C5 (38mm)
Class B4 (54mm)
insulation

Sound insulation

ISO EN 10140 + ISO EN 717

up to 42 db
security

Security

ISO EN 1628 + ISO EN 1629 + ISO EN 1630

RC2: (WK2) *1
thermal-transmittance

Thermal Transmittance

Uw 1.56 W / m2 K (38mm)
Uw 1.06 W / m2 K (54mm)
Uw 0.89 W / m2 K (62mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

up to E1200 (38 mm)
air-permeability

Air permeability

ISO EN 12207 + ISO en 1026

up to Class 4 (38 mm)
wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class B5 (38 mm)
insulation

Sound insulation

ISO EN 10140 + ISO EN 717

up to 38 db
security

Security

ISO EN 1628 + ISO EN 1629 + ISO EN 1630

RC2: (WK2) *1
thermal-transmittance

Thermal Transmittance

Uw 1.61 W / m2 K (38mm)
Uw 1.08 W / m2 K (54mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

up to E1650 (38 mm)
air-permeability

Air permeability

ISO EN 12207 + ISO EN 1026

up to Class 4 (38 mm)
wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class C5 (38 mm)
insulation

Sound insulation

ISO EN 10140 + ISO EN 717

up to 40 db
security

Security

ISO EN 1628 + ISO EN 1629 + ISO EN 1630

RC2: (WK2) *1
thermal-transmittance

Thermal Transmittance

Uw 1.55 W / m2 K (38mm)
Uw 1.07 W / m2 K (54mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

up to Class 8A (38 mm)
up to Class 8A (54mm)
air-permeability

Air permeability

ISO EN 12207 + ISO en 1026

up to Class 3 (38 mm)
up to Class 4 (54mm)
wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class B3 (38 mm)
Class C4 (54mm)
insulation

Sound insulation

ISO EN 10140 + ISO EN 717

up to 38 db
security

Security

RC2: (WK2) 2

RC2: (WK2) *1

Newsletter

OTIIMA - Much more than a window