Transforming Architecture in Ibiza: The Residence at Can Furnet

Ibiza, renowned for its stunning landscapes and vibrant culture, has long been a canvas for architectural innovation. Nestled within this beautiful Mediterranean island, the House in Can Furnet is a testament to the art of refurbishment and extension, showcasing a profound connection between architecture and the environment.  This captivating project centers on the meticulous refurbishment […]

Enhancing Jerusalem’s Skyline: The Intercontinental Hotel Jerusalem

Jerusalem, a city steeped in history and culture, is about to welcome a new architectural gem to its heart: the InterContinental Hotel Jerusalem. This project, comprising two distinctive buildings, promises to redefine luxury and elegance in the city’s hospitality and residential sectors. Designed by the renowned Feigin Architects and featuring OTIIMA Windows, this development is […]

Castilho 203: An Architectural Transformation into Residential Elegance

In a remarkable transformation journey, Castilho 203 evolved from its original office design into a breathtaking residential marvel. This metamorphosis retained the building’s robust structure and ushered in an entirely new architectural narrative. The brilliant minds behind the transformation of Castilho 203 belong to ARX Portugal, an architecture office based in Lisbon. Founded in Berlin […]

Embracing Nature: 5 Minimalist Homes for Outdoor Enthusiasts by OTIIMA

In a world that often feels cluttered and overwhelming, there’s a growing appreciation for minimalist architecture that seamlessly blends with nature. These carefully selected homes, designed for the outdoor enthusiast yearning to connect with the beauty of the natural world, exemplify the perfect harmony between architecture and environment.  Join us as we explore five extraordinary […]

Revitalizing Heritage Architecture: Dyson Global HQ Featuring OTIIMA Minimalist Windows

In the heart of Singapore, the iconic St. James Power Station, an emblem of industrial history, has undergone a stunning transformation to become the new global headquarters of Dyson. This repurposed space now serves as a cutting-edge campus for research, development, and operations teams, providing a functional and inspiring environment. One of the key elements […]

Inside “Barreiro House” with Aires Mateus and Architecture Hunter

The renowned Portuguese architectural practice based in Lisbon, led by architects Manuel Aires Mateus and Francisco Aires Mateus, has received several awards, notably the Valmor Prize, the Secil Prize, the FAD Awards, the Ecola Prize, the Ibero-American Architecture Biennial Awards, several Mies van der Rohe Prize selections. In 2017 he received the Pessoa Prize.   “House […]

5 Exquisite Residential Projects for Your Ultimate Summer Getaway

As summer rolls in, it’s time to escape the hustle and bustle of city life and indulge in a luxurious holiday experience. For discerning individuals who appreciate architectural aesthetics and design details, we have handpicked five residential projects that showcase the remarkable OTIIMA Minimalist Systems. These stunning properties combine modern design, breathtaking landscapes, and seamless […]

Celebrating Minimalism- A Selection Of Captivating Projects

In architecture and design, minimalism is not a new principle; rather, it has been practiced for thousands of years. The belief that “less is more” has inspired designers to create spaces focusing on simplicity, functionality, and the beauty of essential elements.  One material that perfectly embodies this philosophy is concrete. Its clean lines, raw texture, […]

Compare products

Compare products easily by analyzing features and specifications side by side to find the best option for your needs.

thermal-transmittance

Thermal Transmittance

watertightness

Watertightness

air-permeability

Air permeability

wind-resistance

Wind resistance

resistance

Impact resistance

insulation

Sound insulation

security

Security

thermal-transmittance

Thermal Transmittance

Uw Ug = 1,0 (38mm)
Uw Ug = 0.5 (54mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

E1200 (54mm)

(4 classes above 9A) 1

air-permeability

Air permeability

ISO EN 12207 + ISO EN 1026

Class 4

(600 Pa or 119 Km/h) 1 2

wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class C5

(in 6 possible classes) 2

resistance

Impact resistance

ISO EN 12600 + ISO EN 1630

Class 5

(2000 Pa or 200 Km/h)

insulation

Sound insulation

ISO EN 10140 + ISO EN 717

Rw: 42 db (up to)
security

Security

ISO EN 1628 + ISO EN 1629 + ISO EN 1630

RC2: (WK2)

3

thermal-transmittance

Thermal Transmittance

Uw Ug = 1,0 (38mm)
Uw Ug = 0.5 (54mm)
Uw Ug = 0.47 (62mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

E1200

(7 classes above 9A) 1

air-permeability

Air permeability

ISO EN 12207 + ISO en 1026

Class 4

(600 Pa or 110 Km/h) 1

wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class B5

(2000 Pa or 200 Km/h) 1

resistance

Impact resistance

ISO EN 12600 + ISO EN 1630

Class 5 (38mm / 54mm)

1C1 | 2B2 | 1B1 2 (62mm)

insulation

Sound insulation

ISO EN 10140 + ISO EN 717

Rw: 42 db (up to) (38mm / 54mm)

Rw: 44 db (up to) (62mm)

security

Security

ISO EN 1628 + ISO EN 1629 + ISO EN 1630

RC2: (WK2)

3

thermal-transmittance

Thermal Transmittance

Uw Ug = 1.0 (38mm)
Uw Ug = 0.5 (54mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

E1650

(7 Clases superior a 9A) 1

air-permeability

Air permeability

ISO EN 12207 + ISO EN 1026

Class 4

(600 Pa or 110 Km/h) 1

wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class C5

(2000 Pa or 200 Km/h) 1

resistance

Impact resistance

ISO EN 12600 + ISO EN 1630

Class 5
insulation

Sound insulation

ISO EN 10140 + ISO EN 717

Rw: 42 db (up to)
security

Security

ISO EN 1628 + ISO EN 1629 + ISO EN 1630

RC2: (WK2)

2

thermal-transmittance

Thermal Transmittance

Uw Ug = 0.7 (38mm)
Uw Ug = 0.7 (54mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

Class 8A

(450 Pa or 95 km/h)

air-permeability

Air permeability

ISO EN 12207 + ISO en 1026

Class 3

(600 Pa or 110 Km/h)

wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class C5

(2000 Pa or 200 Km/h)

resistance

Impact resistance

ISO EN 12600 + ISO EN 1630

Class 5

(in 6 possible classes)

insulation

Sound insulation

ISO EN 10140 + ISO EN 717

Rw: 38 db (up to)
security

Security

RC2: (WK2) 2

RC2: (WK2)

Newsletter

OTIIMA - Much more than a window

Subscribe