A New Editorial Chapter for OTIIMA

In architecture, meaning is never accidental. Every line and every material has a purpose. At OTIIMA, this same principle guides not only the systems we design but also how we communicate them. The launch of our new catalog and newspaper marks a new editorial chapter that reflects the brand’s maturity, expertise, and the continuous dialogue with architecture at its highest level. 
 

A Guide to OTIIMA Window Solutions 

Traditionally, a catalog is expected to inform, but ours is designed to support architectural thinking. 

This new edition brings together our minimal window systems with a straightforward and technical narrative. Dimensions, performance data, and engineering details coexist with full-scale imagery and carefully framed projects, allowing architects to understand how our systems work and why they exist. 

It is a working tool and a reference. 

The Newspaper as Architectural Discourse 

Alongside the catalog, the OTIIMA Journal expands the conversation. 

Here, we move beyond product and into territory: architecture, climate, landscape, materiality, and performance. The newspaper features interviews with leading architects such as Ana Costa and Laney LA, articles authored by architects, highlighted solutions, and the whole story behind our latest projects.  

The newspaper reflects our belief that engineering gains meaning when it is placed in dialogue with ideas. It is designed to be read, revisited, and kept. 

1. Heydar Aliyev Center – Zaha Hadid

1. Heydar Aliyev Center – Zaha Hadid

OTIIMA Editorial Approach 

This launch signals a clear direction. 

OTIIMA continues to position itself not only as a manufacturer of minimal window systems, but as a strategic partner in architecture, supporting architects and designers from concept to execution. Our editorial approach reflects this role: knowledgeable, accurate, and closely aligned with the realities of architectural practice. 

Every detail of these new editorial pieces, from content structure to graphic language, was developed to reflect that philosophy. 

Explore the New Editions 

The new OTIIMA catalog and newspaper are now available. 

We invite architects, designers, and partners to explore them as they would approach a project: with attention, critical thinking, and curiosity. 

 

Download here: Catalog & Journal

Compare products

Compare products easily by analyzing features and specifications side by side to find the best option for your needs.

thermal-transmittance

Thermal Transmittance

watertightness

Watertightness

air-permeability

Air permeability

wind-resistance

Wind resistance

resistance

Impact resistance

insulation

Sound insulation

security

Security

thermal-transmittance

Thermal Transmittance

Uw Ug = 1,0 (38mm)
Uw Ug = 0.5 (54mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

E1200 (54mm)

(4 classes above 9A) 1

air-permeability

Air permeability

ISO EN 12207 + ISO EN 1026

Class 4

(600 Pa or 119 Km/h) 1 2

wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class C5

(in 6 possible classes) 2

resistance

Impact resistance

ISO EN 12600 + ISO EN 1630

Class 5

(2000 Pa or 200 Km/h)

insulation

Sound insulation

ISO EN 10140 + ISO EN 717

Rw: 42 db (up to)
security

Security

ISO EN 1628 + ISO EN 1629 + ISO EN 1630

RC2: (WK2)

3

thermal-transmittance

Thermal Transmittance

Uw Ug = 1,0 (38mm)
Uw Ug = 0.5 (54mm)
Uw Ug = 0.47 (62mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

E1200

(7 classes above 9A) 1

air-permeability

Air permeability

ISO EN 12207 + ISO en 1026

Class 4

(600 Pa or 110 Km/h) 1

wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class B5

(2000 Pa or 200 Km/h) 1

resistance

Impact resistance

ISO EN 12600 + ISO EN 1630

Class 5 (38mm / 54mm)

1C1 | 2B2 | 1B1 2 (62mm)

insulation

Sound insulation

ISO EN 10140 + ISO EN 717

Rw: 42 db (up to) (38mm / 54mm)

Rw: 44 db (up to) (62mm)

security

Security

ISO EN 1628 + ISO EN 1629 + ISO EN 1630

RC2: (WK2)

3

thermal-transmittance

Thermal Transmittance

Uw Ug = 1.0 (38mm)
Uw Ug = 0.5 (54mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

E1650

(7 Clases superior a 9A) 1

air-permeability

Air permeability

ISO EN 12207 + ISO EN 1026

Class 4

(600 Pa or 110 Km/h) 1

wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class C5

(2000 Pa or 200 Km/h) 1

resistance

Impact resistance

ISO EN 12600 + ISO EN 1630

Class 5
insulation

Sound insulation

ISO EN 10140 + ISO EN 717

Rw: 42 db (up to)
security

Security

ISO EN 1628 + ISO EN 1629 + ISO EN 1630

RC2: (WK2)

2

thermal-transmittance

Thermal Transmittance

Uw Ug = 0.7 (38mm)
Uw Ug = 0.7 (54mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

Class 8A

(450 Pa or 95 km/h)

air-permeability

Air permeability

ISO EN 12207 + ISO en 1026

Class 3

(600 Pa or 110 Km/h)

wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class C5

(2000 Pa or 200 Km/h)

resistance

Impact resistance

ISO EN 12600 + ISO EN 1630

Class 5

(in 6 possible classes)

insulation

Sound insulation

ISO EN 10140 + ISO EN 717

Rw: 38 db (up to)
security

Security

RC2: (WK2) 2

RC2: (WK2)

Newsletter

OTIIMA - Much more than a window

Subscribe