Looking Back at OTIIMA's Most Iconic Tradeshow Stand

Looking Back at OTIIMA’s Most Iconic Tradeshow Stand

 Throwback to a great time at BATIMAT ´22 in Paris, where OTIIMA presented an out-of-the-ordinary stand design concept as well as new takes on their current systems. OTIIMA’S participation at the last edition of BATIMAT marked an important milestone for the brand as received a very positive and warm response due to the warmth and minimalism in the colors, materials and the kind of dreamy space.  

Looking Back at OTIIMA's Most Iconic Tradeshow Stand | OTIIMA

Batimat is the place where construction and architecture professionals meet to share and select innovative products and solutions for the buildings of today and tomorrow. 

On that edition of Batimat, OTIIMA’s main concept and theme “Unwrapped” was to present the brand uncovered, authentic in its entire structure. 

Looking Back at OTIIMA's Most Iconic Tradeshow Stand | OTIIMA

Similar to an iconic and sophisticated watch mechanism, every visitor had the opportunity to observe not only the aesthetic lines and impeccable functionality of the window frame systems but for those who were more attentive could testify, to the dedication and passion of every factory worker and every idea and sketch of brand’s designers and engineers. 

The theme served also as a tribute to all artistic geniuses that everyday work to break the rules without compromising their self-identity and the urge for artistic expression. 

 OTIIMA presented the advanced Fusion 1.0 system, the brand’s trademark and the perfect representation of the natural unification between interior and exterior. 

The details were numerous so that each visitor was able to “paint” and visualize their unique window because it is the promise of OTIIMA: 

To provide a new window for every house, every building, and every space. 

Compare products

Compare products easily by analyzing features and specifications side by side to find the best option for your needs.

thermal-transmittance

Thermal transmittance

watertightness

Watertightness

air-permeability

Air permeability

wind-resistance

Wind resistance

insulation

Acoustic insulation

security

Resistance class

thermal-transmittance

Thermal Transmittance

Uw 1.87 W / m2 K (26mm)
Uw 1.58 W / m2 K (38mm)
Uw 1.07 W / m2 K (54mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

up to E900 (26mm)
up to E1050 (38mm)
up to E1200 (54mm)
air-permeability

Air permeability

ISO EN 12207 + ISO EN 1026

up to Class 3 (26mm)
up to Class 4 (38mm)
up to Class 4 (54mm)
wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class B3 (26mm)
Class C5 (38mm)
Class B4 (54mm)
insulation

Sound insulation

ISO EN 10140 + ISO EN 717

up to 42 db
security

Security

ISO EN 1628 + ISO EN 1629 + ISO EN 1630

RC2: (WK2) *1
thermal-transmittance

Thermal Transmittance

Uw 1.56 W / m2 K (38mm)
Uw 1.06 W / m2 K (54mm)
Uw 0.89 W / m2 K (62mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

up to E1200 (38 mm)
air-permeability

Air permeability

ISO EN 12207 + ISO en 1026

up to Class 4 (38 mm)
wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class B5 (38 mm)
insulation

Sound insulation

ISO EN 10140 + ISO EN 717

up to 38 db
security

Security

ISO EN 1628 + ISO EN 1629 + ISO EN 1630

RC2: (WK2) *1
thermal-transmittance

Thermal Transmittance

Uw 1.61 W / m2 K (38mm)
Uw 1.08 W / m2 K (54mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

up to E1650 (38 mm)
air-permeability

Air permeability

ISO EN 12207 + ISO EN 1026

up to Class 4 (38 mm)
wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class C5 (38 mm)
insulation

Sound insulation

ISO EN 10140 + ISO EN 717

up to 40 db
security

Security

ISO EN 1628 + ISO EN 1629 + ISO EN 1630

RC2: (WK2) *1
thermal-transmittance

Thermal Transmittance

Uw 1.55 W / m2 K (38mm)
Uw 1.07 W / m2 K (54mm)

watertightness

Watertightness

ISO EN 12208 + ISO EN 1027

up to Class 8A (38 mm)
up to Class 8A (54mm)
air-permeability

Air permeability

ISO EN 12207 + ISO en 1026

up to Class 3 (38 mm)
up to Class 4 (54mm)
wind-resistance

Wind resistance

ISO EN 12210 + ISO EN 12211

Class B3 (38 mm)
Class C4 (54mm)
insulation

Sound insulation

ISO EN 10140 + ISO EN 717

up to 38 db
security

Security

RC2: (WK2) 2

RC2: (WK2) *1